3-D Corneal Modeling System

Richard Mammone, Martin Gersten, Dennis J. Gormley, Richard S. Koplin, Virginia L. Lubkin

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

New surgical procedures have been introduced recently that provide refractive correction to replace the use of eyeglasses or contact lenses. The procedures involve reshaping the cornea to compensate for the optical anomalies of astigmatism and nearsightedness. Although thousands of operations are currently performed in the U.S., there are no instruments available for monitoring the results. Thus, a critical need has arisen to inspect and measure the cornea's surface both before and after surgery. In this paper an instrument is presented which provides a detailed topographical model of an individual’s cornea. The method uses a novel structured light source. The cornea is modeled as a convex mirror which forms a virtual image of the structured light source. A single image is recorded from the patient’s cornea. The depth is obtained from triangulation between the acquired image and a reference image of a sphere. The reconstruction of the depth map is complicated by the fact that the magnification used in recording the image varies with the radius of curvature of the cornea. An iterative method is presented which solves for the radius of curvature despite the variation in magnification. The virtual image is digitized and the instantaneous curvature of the cornea is obtained. The instantaneous curvature is displayed in units of optical power (diopters). This display provides the opthalmologist or optometrist with the essential optical properties of the cornea.

Original languageEnglish (US)
Pages (from-to)66-72
Number of pages7
JournalIEEE Transactions on Biomedical Engineering
Volume37
Issue number1
DOIs
StatePublished - Jan 1 1990

Fingerprint

Light sources
Eyeglasses
Contact lenses
Triangulation
Iterative methods
Surgery
Mirrors
Optical properties
Display devices
Monitoring

All Science Journal Classification (ASJC) codes

  • Biomedical Engineering

Cite this

Mammone, R., Gersten, M., Gormley, D. J., Koplin, R. S., & Lubkin, V. L. (1990). 3-D Corneal Modeling System. IEEE Transactions on Biomedical Engineering, 37(1), 66-72. https://doi.org/10.1109/10.43617
Mammone, Richard ; Gersten, Martin ; Gormley, Dennis J. ; Koplin, Richard S. ; Lubkin, Virginia L. / 3-D Corneal Modeling System. In: IEEE Transactions on Biomedical Engineering. 1990 ; Vol. 37, No. 1. pp. 66-72.
@article{dd6896b86185492faedf1b6fe62f3f3d,
title = "3-D Corneal Modeling System",
abstract = "New surgical procedures have been introduced recently that provide refractive correction to replace the use of eyeglasses or contact lenses. The procedures involve reshaping the cornea to compensate for the optical anomalies of astigmatism and nearsightedness. Although thousands of operations are currently performed in the U.S., there are no instruments available for monitoring the results. Thus, a critical need has arisen to inspect and measure the cornea's surface both before and after surgery. In this paper an instrument is presented which provides a detailed topographical model of an individual’s cornea. The method uses a novel structured light source. The cornea is modeled as a convex mirror which forms a virtual image of the structured light source. A single image is recorded from the patient’s cornea. The depth is obtained from triangulation between the acquired image and a reference image of a sphere. The reconstruction of the depth map is complicated by the fact that the magnification used in recording the image varies with the radius of curvature of the cornea. An iterative method is presented which solves for the radius of curvature despite the variation in magnification. The virtual image is digitized and the instantaneous curvature of the cornea is obtained. The instantaneous curvature is displayed in units of optical power (diopters). This display provides the opthalmologist or optometrist with the essential optical properties of the cornea.",
author = "Richard Mammone and Martin Gersten and Gormley, {Dennis J.} and Koplin, {Richard S.} and Lubkin, {Virginia L.}",
year = "1990",
month = "1",
day = "1",
doi = "10.1109/10.43617",
language = "English (US)",
volume = "37",
pages = "66--72",
journal = "IEEE Transactions on Biomedical Engineering",
issn = "0018-9294",
publisher = "IEEE Computer Society",
number = "1",

}

Mammone, R, Gersten, M, Gormley, DJ, Koplin, RS & Lubkin, VL 1990, '3-D Corneal Modeling System', IEEE Transactions on Biomedical Engineering, vol. 37, no. 1, pp. 66-72. https://doi.org/10.1109/10.43617

3-D Corneal Modeling System. / Mammone, Richard; Gersten, Martin; Gormley, Dennis J.; Koplin, Richard S.; Lubkin, Virginia L.

In: IEEE Transactions on Biomedical Engineering, Vol. 37, No. 1, 01.01.1990, p. 66-72.

Research output: Contribution to journalArticle

TY - JOUR

T1 - 3-D Corneal Modeling System

AU - Mammone, Richard

AU - Gersten, Martin

AU - Gormley, Dennis J.

AU - Koplin, Richard S.

AU - Lubkin, Virginia L.

PY - 1990/1/1

Y1 - 1990/1/1

N2 - New surgical procedures have been introduced recently that provide refractive correction to replace the use of eyeglasses or contact lenses. The procedures involve reshaping the cornea to compensate for the optical anomalies of astigmatism and nearsightedness. Although thousands of operations are currently performed in the U.S., there are no instruments available for monitoring the results. Thus, a critical need has arisen to inspect and measure the cornea's surface both before and after surgery. In this paper an instrument is presented which provides a detailed topographical model of an individual’s cornea. The method uses a novel structured light source. The cornea is modeled as a convex mirror which forms a virtual image of the structured light source. A single image is recorded from the patient’s cornea. The depth is obtained from triangulation between the acquired image and a reference image of a sphere. The reconstruction of the depth map is complicated by the fact that the magnification used in recording the image varies with the radius of curvature of the cornea. An iterative method is presented which solves for the radius of curvature despite the variation in magnification. The virtual image is digitized and the instantaneous curvature of the cornea is obtained. The instantaneous curvature is displayed in units of optical power (diopters). This display provides the opthalmologist or optometrist with the essential optical properties of the cornea.

AB - New surgical procedures have been introduced recently that provide refractive correction to replace the use of eyeglasses or contact lenses. The procedures involve reshaping the cornea to compensate for the optical anomalies of astigmatism and nearsightedness. Although thousands of operations are currently performed in the U.S., there are no instruments available for monitoring the results. Thus, a critical need has arisen to inspect and measure the cornea's surface both before and after surgery. In this paper an instrument is presented which provides a detailed topographical model of an individual’s cornea. The method uses a novel structured light source. The cornea is modeled as a convex mirror which forms a virtual image of the structured light source. A single image is recorded from the patient’s cornea. The depth is obtained from triangulation between the acquired image and a reference image of a sphere. The reconstruction of the depth map is complicated by the fact that the magnification used in recording the image varies with the radius of curvature of the cornea. An iterative method is presented which solves for the radius of curvature despite the variation in magnification. The virtual image is digitized and the instantaneous curvature of the cornea is obtained. The instantaneous curvature is displayed in units of optical power (diopters). This display provides the opthalmologist or optometrist with the essential optical properties of the cornea.

UR - http://www.scopus.com/inward/record.url?scp=0025327335&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025327335&partnerID=8YFLogxK

U2 - 10.1109/10.43617

DO - 10.1109/10.43617

M3 - Article

C2 - 2303272

AN - SCOPUS:0025327335

VL - 37

SP - 66

EP - 72

JO - IEEE Transactions on Biomedical Engineering

JF - IEEE Transactions on Biomedical Engineering

SN - 0018-9294

IS - 1

ER -

Mammone R, Gersten M, Gormley DJ, Koplin RS, Lubkin VL. 3-D Corneal Modeling System. IEEE Transactions on Biomedical Engineering. 1990 Jan 1;37(1):66-72. https://doi.org/10.1109/10.43617