T1 - Aerosolization of particles from a bubbling liquid
T2 - Characteristics and generator development
AU - Ulevicius, Vidmantas
AU - Willeke, Klaus
AU - Grinshpun, Sergey A.
AU - Donnelly, Jean
AU - Lin, Xuejun
AU - Mainelis, Gediminas
PY - 1997/1/1
Y1 - 1997/1/1
N2 - A new aerosol generator is introduced in which particles suspended in a liquid are aerosolized by gentle bubble bursting. Tangential injection of dry air to the bubbling surface dries the airborne droplets immediately after aerosolization so that they rapidly shrink in size and are carried out from the generator by inward and upward swirling air motion. The new generator has been evaluated with monodisperse PSL particles in the size range of 0.73–5.1 μm and with a saline solution using a time-of-flight aerodynamic particle size spectrometer (Aerosizer). It was found that, in contrast to pneumatic nebulization (e.g., with a Collison nebulizer), the new generator's output in undesirable liquid droplets is very small, while its output in dry PSL particles is high. When using the new aerosol generator, a minimum number of the nebulized droplets is returned to the liquid pool, thus optimizing the number of particles available as test aerosols. The aerosol concentration was found to be constant and stable for at least 30 min with the prototype generator tested. It is shown that the relative humidity of the effluent flow can be regulated. For microorganisms aerosolized by this generator, the shear stress is expected to be considerably lower than in conventional aerosol generators.
AB - A new aerosol generator is introduced in which particles suspended in a liquid are aerosolized by gentle bubble bursting. Tangential injection of dry air to the bubbling surface dries the airborne droplets immediately after aerosolization so that they rapidly shrink in size and are carried out from the generator by inward and upward swirling air motion. The new generator has been evaluated with monodisperse PSL particles in the size range of 0.73–5.1 μm and with a saline solution using a time-of-flight aerodynamic particle size spectrometer (Aerosizer). It was found that, in contrast to pneumatic nebulization (e.g., with a Collison nebulizer), the new generator's output in undesirable liquid droplets is very small, while its output in dry PSL particles is high. When using the new aerosol generator, a minimum number of the nebulized droplets is returned to the liquid pool, thus optimizing the number of particles available as test aerosols. The aerosol concentration was found to be constant and stable for at least 30 min with the prototype generator tested. It is shown that the relative humidity of the effluent flow can be regulated. For microorganisms aerosolized by this generator, the shear stress is expected to be considerably lower than in conventional aerosol generators.
UR - http://www.scopus.com/inward/record.url?scp=0030620453&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030620453&partnerID=8YFLogxK
U2 - 10.1080/02786829708965423
DO - 10.1080/02786829708965423
M3 - Article
AN - SCOPUS:0030620453
SN - 0278-6826
VL - 26
SP - 175
EP - 190
JO - Aerosol Science and Technology
JF - Aerosol Science and Technology
IS - 2
ER -