TY - JOUR
T1 - Blood flow and high-energy phosphates in microregions of left ventricular subendocardium
AU - Kleinert, H. D.
AU - Weiss, H. R.
PY - 1981
Y1 - 1981
N2 - Blood flow and high-energy phosphate (HEP) content were determined simultaneously in multiple microregions of left ventricular subendocardium in 29 normal anesthetized open-chest rabbits by use of a new micromethod to determine whether a direct linear relationship existed between these parameters. Tissue samples weighed 1-2 mg. ATP and creatine phosphate (CP) content were quantitated in quick-frozen hearts by fluorometry at sites where tissue perfusion was measured by H2 clearance by use of bare-tipped platinum electrodes. A series of validation studies were conducted to ensure that 1) no significant damage to the tissue surrounding the electrode occurred during the period of experimentation and 2) no significant loss of biochemical constituents had occurred due to labile processes during freezing or storage of the tissue. Blood flow, ATP, and CP values averaged 79.1 ± 24.1 (SD) ml/min-1/100 g-1, 4.9 ± 1.3 μmol/g tissue, and 8.0 ± 3.0 μmol/g tissue, respectively, and are similar to those reported in studies using larger tissue samples. Correlation between the heterogeneous distribution of tissue perfusion and HEP revealed no direct linear relationship between these parameters in the normal unstressed rabbit subendocardium.
AB - Blood flow and high-energy phosphate (HEP) content were determined simultaneously in multiple microregions of left ventricular subendocardium in 29 normal anesthetized open-chest rabbits by use of a new micromethod to determine whether a direct linear relationship existed between these parameters. Tissue samples weighed 1-2 mg. ATP and creatine phosphate (CP) content were quantitated in quick-frozen hearts by fluorometry at sites where tissue perfusion was measured by H2 clearance by use of bare-tipped platinum electrodes. A series of validation studies were conducted to ensure that 1) no significant damage to the tissue surrounding the electrode occurred during the period of experimentation and 2) no significant loss of biochemical constituents had occurred due to labile processes during freezing or storage of the tissue. Blood flow, ATP, and CP values averaged 79.1 ± 24.1 (SD) ml/min-1/100 g-1, 4.9 ± 1.3 μmol/g tissue, and 8.0 ± 3.0 μmol/g tissue, respectively, and are similar to those reported in studies using larger tissue samples. Correlation between the heterogeneous distribution of tissue perfusion and HEP revealed no direct linear relationship between these parameters in the normal unstressed rabbit subendocardium.
UR - http://www.scopus.com/inward/record.url?scp=16744365333&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=16744365333&partnerID=8YFLogxK
U2 - 10.1152/ajpheart.1981.240.5.h804
DO - 10.1152/ajpheart.1981.240.5.h804
M3 - Article
C2 - 7235040
AN - SCOPUS:16744365333
SN - 0363-6135
VL - 9
SP - H804-H810
JO - American Journal of Physiology - Heart and Circulatory Physiology
JF - American Journal of Physiology - Heart and Circulatory Physiology
IS - 5
ER -