TY - JOUR
T1 - Determination of unbound platinum concentrations in human plasma using ultrafiltration and precipitation methods
AU - Wen, Xia
AU - Doherty, Cathleen
AU - Thompson, Lauren E.
AU - Kim, Christine
AU - Buckley, Brian S.
AU - Jaimes, Edgar A.
AU - Joy, Melanie S.
AU - Aleksunes, Lauren M.
N1 - Publisher Copyright:
© 2024 The Authors
PY - 2024/7/1
Y1 - 2024/7/1
N2 - Quantification of the unbound portion of platinum (Pt) in human plasma is important for assessing the pharmacokinetics of the chemotherapeutic drug cisplatin. In this study, we sought to compare the recovery of unbound Pt using Nanosep® filters to 1) traditional filters (Centrifree®, Centrisart®, Amicon®) or trichloroacetic acid (TCA) protein precipitation, and 2) unbound, bound, and total Pt concentrations in clinical specimens. For the tested filters, the impact of 1) molecular weight cut-offs, 2) centrifugation force, and 3) total Pt concentration on Pt binding in human plasma was evaluated. Pt was quantified using inductively coupled-plasma mass spectrometry. In human plasma spiked with 0.9 μg/mL Pt, the percent of unbound Pt increased at higher centrifugation speeds. By comparison, the percent of unbound Pt was highest (42.1%) following TCA protein precipitation. When total Pt was ≤0.9 μg/mL, unbound Pt (∼20–30%) was consistent across filters. Conversely, when plasma was spiked with Pt exceeding 0.9 μg/mL, the percent of unbound Pt increased from 36.5 to 48% using ultrafiltration, compared to 63.4% to 79% with TCA precipitation. In patients receiving cisplatin-containing chemotherapy, the fraction of unbound Pt at concentrations exceeding 0.9 μg/mL ranged between 35 and 90%. Moreover, the unbound fraction of Pt in plasma correlated with the concentration of unbound (R2 = 0.738) and total Pt (R2 = 0.335). In summary, this study demonstrates that 1) the percent of unbound Pt is influenced by total and unbound Pt levels in vitro and in clinical specimens, and 2) ultrafiltration with Nanosep® filters is a feasible method for quantifying unbound Pt concentrations in human plasma.
AB - Quantification of the unbound portion of platinum (Pt) in human plasma is important for assessing the pharmacokinetics of the chemotherapeutic drug cisplatin. In this study, we sought to compare the recovery of unbound Pt using Nanosep® filters to 1) traditional filters (Centrifree®, Centrisart®, Amicon®) or trichloroacetic acid (TCA) protein precipitation, and 2) unbound, bound, and total Pt concentrations in clinical specimens. For the tested filters, the impact of 1) molecular weight cut-offs, 2) centrifugation force, and 3) total Pt concentration on Pt binding in human plasma was evaluated. Pt was quantified using inductively coupled-plasma mass spectrometry. In human plasma spiked with 0.9 μg/mL Pt, the percent of unbound Pt increased at higher centrifugation speeds. By comparison, the percent of unbound Pt was highest (42.1%) following TCA protein precipitation. When total Pt was ≤0.9 μg/mL, unbound Pt (∼20–30%) was consistent across filters. Conversely, when plasma was spiked with Pt exceeding 0.9 μg/mL, the percent of unbound Pt increased from 36.5 to 48% using ultrafiltration, compared to 63.4% to 79% with TCA precipitation. In patients receiving cisplatin-containing chemotherapy, the fraction of unbound Pt at concentrations exceeding 0.9 μg/mL ranged between 35 and 90%. Moreover, the unbound fraction of Pt in plasma correlated with the concentration of unbound (R2 = 0.738) and total Pt (R2 = 0.335). In summary, this study demonstrates that 1) the percent of unbound Pt is influenced by total and unbound Pt levels in vitro and in clinical specimens, and 2) ultrafiltration with Nanosep® filters is a feasible method for quantifying unbound Pt concentrations in human plasma.
KW - Cisplatin
KW - Nanosep® filter
KW - TCA precipitation
KW - Ultrafiltration
KW - Unbound Pt
UR - http://www.scopus.com/inward/record.url?scp=85197077921&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85197077921&partnerID=8YFLogxK
U2 - 10.1016/j.vascn.2024.107535
DO - 10.1016/j.vascn.2024.107535
M3 - Article
C2 - 38955285
AN - SCOPUS:85197077921
SN - 1056-8719
VL - 128
JO - Journal of Pharmacological and Toxicological Methods
JF - Journal of Pharmacological and Toxicological Methods
M1 - 107535
ER -