TY - JOUR
T1 - Discarding the initial aliquot of blood does not reduce contamination rates in intravenous-catheter-drawn blood cultures
AU - Dwivedi, Sukrut
AU - Bhalla, Rohit
AU - Hoover, Donald R.
AU - Weinstein, Melvin P.
PY - 2009/9
Y1 - 2009/9
N2 - Although venipuncture is the preferred method for obtaining blood cultures, specimens often are obtained from intravenous catheters (IVC). For IVC-drawn blood cultures, some authorities recommend discarding the initial 5 to 10 ml of blood to reduce contamination and remove potential inhibitory substances. To determine whether this practice reduced contamination rates (CR), we assessed the results of IVC-drawn blood cultures for adults. Thirty milliliters of blood was obtained aseptically. The first 10 ml, rather than being discarded, was inoculated into an aerobic culture vial. Using a second sterile syringe, 20 ml of blood was obtained and inoculated in 10-ml aliquots to aerobic and anaerobic culture vials. Positive cultures were evaluated to assess clinical significance (true versus contaminant). Out of 653 IVC-drawn blood culture pairs, both vials were contaminated in 38 pairs (5.8%); only the "discard" vial was contaminated in 33 (5.1%); and only the "standard" vial was contaminated in 31 (4.7%). Overall CR were 10.9% for the discard vial versus 10.5% for the standard vial (P = 0.90). We conclude that discarding an initial aliquot of blood when obtaining blood cultures from IVCs does not reduce CR.
AB - Although venipuncture is the preferred method for obtaining blood cultures, specimens often are obtained from intravenous catheters (IVC). For IVC-drawn blood cultures, some authorities recommend discarding the initial 5 to 10 ml of blood to reduce contamination and remove potential inhibitory substances. To determine whether this practice reduced contamination rates (CR), we assessed the results of IVC-drawn blood cultures for adults. Thirty milliliters of blood was obtained aseptically. The first 10 ml, rather than being discarded, was inoculated into an aerobic culture vial. Using a second sterile syringe, 20 ml of blood was obtained and inoculated in 10-ml aliquots to aerobic and anaerobic culture vials. Positive cultures were evaluated to assess clinical significance (true versus contaminant). Out of 653 IVC-drawn blood culture pairs, both vials were contaminated in 38 pairs (5.8%); only the "discard" vial was contaminated in 33 (5.1%); and only the "standard" vial was contaminated in 31 (4.7%). Overall CR were 10.9% for the discard vial versus 10.5% for the standard vial (P = 0.90). We conclude that discarding an initial aliquot of blood when obtaining blood cultures from IVCs does not reduce CR.
UR - http://www.scopus.com/inward/record.url?scp=69949089851&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=69949089851&partnerID=8YFLogxK
U2 - 10.1128/JCM.00292-09
DO - 10.1128/JCM.00292-09
M3 - Article
C2 - 19641064
AN - SCOPUS:69949089851
SN - 0095-1137
VL - 47
SP - 2950
EP - 2951
JO - Journal of clinical microbiology
JF - Journal of clinical microbiology
IS - 9
ER -