Distal screw targeting of interlocking nails

J. P. Rao, M. P. Allegra, Joseph Benevenia, T. A. Dauhajre

Research output: Contribution to journalArticle

30 Citations (Scopus)

Abstract

Successful placement of the distal interlocking screws into the Grosse-Kempf nail is a demanding procedure due in part to deformation of the nail during insertion and to inaccuracy of the targeting device supplied with the system. The authors suggest an alternative approach. After placement of the nail in a tibia or femur, a Kirschner wire (K-wire) is directed through the distal transfixation hole under fluoroscopic control. A second Grosse-Kempf nail is placed alongside the limb with the K-wire passing through the corresponding distal hole. The more proximal hole on the nail serves as a targeting guide for a more proximal wire. Once correct placement of the wires is confirmed roentgenographically, the near cortex is opened with a cannulated drill passed over the wires. The wires are removed, the opposite cortices are drilled, and the screws are placed. In 25 consecutive distally locked nailings (eight tibiae and 17 femora), the technique was easily mastered, decreasing the roentgenogram exposure when compared to freehand techniques.

Original languageEnglish (US)
Pages (from-to)245-248
Number of pages4
JournalClinical orthopaedics and related research
Issue number238
StatePublished - Jan 1 1989
Externally publishedYes

Fingerprint

Nails
Bone Wires
Tibia
Femur
Mandrillus
Extremities
Equipment and Supplies

All Science Journal Classification (ASJC) codes

  • Surgery
  • Orthopedics and Sports Medicine

Cite this

Rao, J. P., Allegra, M. P., Benevenia, J., & Dauhajre, T. A. (1989). Distal screw targeting of interlocking nails. Clinical orthopaedics and related research, (238), 245-248.
Rao, J. P. ; Allegra, M. P. ; Benevenia, Joseph ; Dauhajre, T. A. / Distal screw targeting of interlocking nails. In: Clinical orthopaedics and related research. 1989 ; No. 238. pp. 245-248.
@article{168e05b1ee884fe7bdaa38323b6d8176,
title = "Distal screw targeting of interlocking nails",
abstract = "Successful placement of the distal interlocking screws into the Grosse-Kempf nail is a demanding procedure due in part to deformation of the nail during insertion and to inaccuracy of the targeting device supplied with the system. The authors suggest an alternative approach. After placement of the nail in a tibia or femur, a Kirschner wire (K-wire) is directed through the distal transfixation hole under fluoroscopic control. A second Grosse-Kempf nail is placed alongside the limb with the K-wire passing through the corresponding distal hole. The more proximal hole on the nail serves as a targeting guide for a more proximal wire. Once correct placement of the wires is confirmed roentgenographically, the near cortex is opened with a cannulated drill passed over the wires. The wires are removed, the opposite cortices are drilled, and the screws are placed. In 25 consecutive distally locked nailings (eight tibiae and 17 femora), the technique was easily mastered, decreasing the roentgenogram exposure when compared to freehand techniques.",
author = "Rao, {J. P.} and Allegra, {M. P.} and Joseph Benevenia and Dauhajre, {T. A.}",
year = "1989",
month = "1",
day = "1",
language = "English (US)",
pages = "245--248",
journal = "Clinical Orthopaedics and Related Research",
issn = "0009-921X",
publisher = "Springer New York",
number = "238",

}

Rao, JP, Allegra, MP, Benevenia, J & Dauhajre, TA 1989, 'Distal screw targeting of interlocking nails', Clinical orthopaedics and related research, no. 238, pp. 245-248.

Distal screw targeting of interlocking nails. / Rao, J. P.; Allegra, M. P.; Benevenia, Joseph; Dauhajre, T. A.

In: Clinical orthopaedics and related research, No. 238, 01.01.1989, p. 245-248.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Distal screw targeting of interlocking nails

AU - Rao, J. P.

AU - Allegra, M. P.

AU - Benevenia, Joseph

AU - Dauhajre, T. A.

PY - 1989/1/1

Y1 - 1989/1/1

N2 - Successful placement of the distal interlocking screws into the Grosse-Kempf nail is a demanding procedure due in part to deformation of the nail during insertion and to inaccuracy of the targeting device supplied with the system. The authors suggest an alternative approach. After placement of the nail in a tibia or femur, a Kirschner wire (K-wire) is directed through the distal transfixation hole under fluoroscopic control. A second Grosse-Kempf nail is placed alongside the limb with the K-wire passing through the corresponding distal hole. The more proximal hole on the nail serves as a targeting guide for a more proximal wire. Once correct placement of the wires is confirmed roentgenographically, the near cortex is opened with a cannulated drill passed over the wires. The wires are removed, the opposite cortices are drilled, and the screws are placed. In 25 consecutive distally locked nailings (eight tibiae and 17 femora), the technique was easily mastered, decreasing the roentgenogram exposure when compared to freehand techniques.

AB - Successful placement of the distal interlocking screws into the Grosse-Kempf nail is a demanding procedure due in part to deformation of the nail during insertion and to inaccuracy of the targeting device supplied with the system. The authors suggest an alternative approach. After placement of the nail in a tibia or femur, a Kirschner wire (K-wire) is directed through the distal transfixation hole under fluoroscopic control. A second Grosse-Kempf nail is placed alongside the limb with the K-wire passing through the corresponding distal hole. The more proximal hole on the nail serves as a targeting guide for a more proximal wire. Once correct placement of the wires is confirmed roentgenographically, the near cortex is opened with a cannulated drill passed over the wires. The wires are removed, the opposite cortices are drilled, and the screws are placed. In 25 consecutive distally locked nailings (eight tibiae and 17 femora), the technique was easily mastered, decreasing the roentgenogram exposure when compared to freehand techniques.

UR - http://www.scopus.com/inward/record.url?scp=0024597239&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024597239&partnerID=8YFLogxK

M3 - Article

C2 - 2910610

AN - SCOPUS:0024597239

SP - 245

EP - 248

JO - Clinical Orthopaedics and Related Research

JF - Clinical Orthopaedics and Related Research

SN - 0009-921X

IS - 238

ER -