Abstract
Two fiberoptic infrared multi-spectral radiometers were constructed for measurements of the temperature and the emissivity of gray bodies whose temperatures were close to room temperature (40-70°C). In one radiometer, the different spectral regions were obtained by using standard bulk interference filters, and in a second radiometer, the different spectral regions were obtained by using hollow glass waveguides (HGWs) as filters. Using these two radiometers, we carried out temperature and emissivity measurements of three gray bodies which had high emissivity (ε=0.97), medium emissivity (ε=0.71) and low emissivity (ε=0.025). We present the results obtained for these gray bodies and discuss the advantages and disadvantages in using each of the radiometers.
Original language | English (US) |
---|---|
Pages (from-to) | 116-124 |
Number of pages | 9 |
Journal | Proceedings of SPIE - The International Society for Optical Engineering |
Volume | 5363 |
DOIs | |
State | Published - 2004 |
Event | Emerging Optoelectronic Applications - San Jose, CA, United States Duration: Jan 26 2004 → Jan 27 2004 |
All Science Journal Classification (ASJC) codes
- Electronic, Optical and Magnetic Materials
- Condensed Matter Physics
- Computer Science Applications
- Applied Mathematics
- Electrical and Electronic Engineering
Keywords
- Emissivity
- Hollow waveguides
- Infrared fibers
- Multi-spectral
- Radiometry
- Silver halide
- Temperature