TY - JOUR
T1 - Low-flow and high-flow neurosurgical bypass and anastomosis training models using human and bovine placental vessels
T2 - A histological analysis and validation study
AU - Belykh, Evgenii
AU - Lei, Ting
AU - Safavi-Abbasi, Sam
AU - Yagmurlu, Kaan
AU - Almefty, Rami O.
AU - Sun, Hai
AU - Almefty, Kaith K.
AU - Belykh, Olga
AU - Byvaltsev, Vadim A.
AU - Spetzler, Robert F.
AU - Nakaji, Peter
AU - Preul, Mark C.
N1 - Publisher Copyright:
© AANS, 2016.
PY - 2016/10
Y1 - 2016/10
N2 - Objective: Microvascular anastomosis is a basic neurosurgical technique that should be mastered in the laboratory. Human and bovine placentas have been proposed as convenient surgical practice models; however, the histologic characteristics of these tissues have not been compared with human cerebral vessels, and the models have not been validated as simulation training models. In this study, the authors assessed the construct, face, and content validities of microvascular bypass simulation models that used human and bovine placental vessels. Methods: The characteristics of vessel segments from 30 human and 10 bovine placentas were assessed anatomically and histologically. Microvascular bypasses were performed on the placenta models according to a delineated training module by "trained" participants (10 practicing neurosurgeons and 7 residents with microsurgical experience) and "untrained" participants (10 medical students and 3 residents without experience). Anastomosis performance and impressions of the model were assessed using the Northwestern Objective Microanastomosis Assessment Tool (NOMAT) scale and a posttraining survey. Results: Human placental arteries were found to approximate the M2-M4 cerebral and superficial temporal arteries, and bovine placental veins were found to approximate the internal carotid and radial arteries. The mean NOMAT performance score was 37.2 ± 7.0 in the untrained group versus 62.7 ± 6.1 in the trained group (p < 0.01; construct validity). A 50% probability of allocation to either group corresponded to 50 NOMAT points. In the posttraining survey, 16 of 17 of the trained participants (94%) scored the model's replication of real bypass surgery as high, and 16 of 17 (94%) scored the difficulty as "the same" (face validity). All participants, 30 of 30 (100%), answered positively to questions regarding the ability of the model to improve microsurgical technique (content validity). Conclusions Human placental arteries and bovine placental veins are convenient, anatomically relevant, and beneficial models for microneurosurgical training. Microanastomosis simulation using these models has high face, content, and construct validities. A NOMAT score of more than 50 indicated successful performance of the microanastomosis tasks.
AB - Objective: Microvascular anastomosis is a basic neurosurgical technique that should be mastered in the laboratory. Human and bovine placentas have been proposed as convenient surgical practice models; however, the histologic characteristics of these tissues have not been compared with human cerebral vessels, and the models have not been validated as simulation training models. In this study, the authors assessed the construct, face, and content validities of microvascular bypass simulation models that used human and bovine placental vessels. Methods: The characteristics of vessel segments from 30 human and 10 bovine placentas were assessed anatomically and histologically. Microvascular bypasses were performed on the placenta models according to a delineated training module by "trained" participants (10 practicing neurosurgeons and 7 residents with microsurgical experience) and "untrained" participants (10 medical students and 3 residents without experience). Anastomosis performance and impressions of the model were assessed using the Northwestern Objective Microanastomosis Assessment Tool (NOMAT) scale and a posttraining survey. Results: Human placental arteries were found to approximate the M2-M4 cerebral and superficial temporal arteries, and bovine placental veins were found to approximate the internal carotid and radial arteries. The mean NOMAT performance score was 37.2 ± 7.0 in the untrained group versus 62.7 ± 6.1 in the trained group (p < 0.01; construct validity). A 50% probability of allocation to either group corresponded to 50 NOMAT points. In the posttraining survey, 16 of 17 of the trained participants (94%) scored the model's replication of real bypass surgery as high, and 16 of 17 (94%) scored the difficulty as "the same" (face validity). All participants, 30 of 30 (100%), answered positively to questions regarding the ability of the model to improve microsurgical technique (content validity). Conclusions Human placental arteries and bovine placental veins are convenient, anatomically relevant, and beneficial models for microneurosurgical training. Microanastomosis simulation using these models has high face, content, and construct validities. A NOMAT score of more than 50 indicated successful performance of the microanastomosis tasks.
KW - Cerebral revascularization
KW - Microvascular anastomosis training
KW - NOMAT
KW - Placenta
KW - Surgical practice
KW - Surgical simulation neurosurgical training
KW - Vascular disorders
UR - http://www.scopus.com/inward/record.url?scp=84990234215&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84990234215&partnerID=8YFLogxK
U2 - 10.3171/2015.8.JNS151346
DO - 10.3171/2015.8.JNS151346
M3 - Article
C2 - 26799298
AN - SCOPUS:84990234215
SN - 0022-3085
VL - 125
SP - 915
EP - 928
JO - Journal of Neurosurgery
JF - Journal of Neurosurgery
IS - 4
ER -