TY - JOUR
T1 - Preprocessing of HPLC trace impurity patterns by wavelet packets for pharmaceutical fingerprinting using artificial neural networks
AU - Collantes, Elizabeth R.
AU - Duta, Radu
AU - Welsh, William J.
AU - Zielinski, Walter L.
AU - Brower, James
PY - 1997
Y1 - 1997
N2 - The immediate objective of this research program is to evaluate several computer-based classifiers as potential tools for pharmaceutical fingerprinting based on analysis of HPLC trace organic impurity patterns. In the present study, wavelet packets (WPs) are investigated for use as a preprocessor of the chromatographic data taken from commercial samples of L-tryptophan (LT) to extract input data appropriate for classifying the samples according to manufacturer using artificial neural networks (ANNs) and the standard classifiers KNN and SIMCA. Using the Haar function, WP decompositions for levels L = 0-10 were generated for the trace impurity patterns of 253 chromatograms corresponding to LT samples that had been produced by six commercial manufacturers. Input sets of N = 20, 30, 40, and 50 inputs were constructed, each one consisting of the first N/2 WP coefficients and corresponding positions from the overall best level (L = 2). The number of hidden nodes in the ANNs was also varied to optimize performance. Optimal ANN performance based on percent correct classifications of test set data was achieved by ANN-30-30-6 (97%) and ANN-20-10-6 (94%), where the integers refer to the numbers of input, hidden, and output nodes, respectively. This performance equals or exceeds that obtained previoush (Welsh, W.J.; et al. Anal. Chem. 1996, 68, 3473) using 46 inputs from a so-called Window preprocessor (93%). KNN performance with 20 inputs (97%) or 30 inputs (90%) from the WP preprocessor also exceeded that obtained from the Window preprocessor (85%), while SIMCA performance with 20 inputs (86%) or 30 inputs (82%) from the WP preprocessor was slightly inferior to that obtained from the Window preprocessor (87%). These results indicate that, at least for the ANN and KNN classifiers considered here, the WP preprocessor can yield superior performance and with fewer inputs compared to the Window preprocessor.
AB - The immediate objective of this research program is to evaluate several computer-based classifiers as potential tools for pharmaceutical fingerprinting based on analysis of HPLC trace organic impurity patterns. In the present study, wavelet packets (WPs) are investigated for use as a preprocessor of the chromatographic data taken from commercial samples of L-tryptophan (LT) to extract input data appropriate for classifying the samples according to manufacturer using artificial neural networks (ANNs) and the standard classifiers KNN and SIMCA. Using the Haar function, WP decompositions for levels L = 0-10 were generated for the trace impurity patterns of 253 chromatograms corresponding to LT samples that had been produced by six commercial manufacturers. Input sets of N = 20, 30, 40, and 50 inputs were constructed, each one consisting of the first N/2 WP coefficients and corresponding positions from the overall best level (L = 2). The number of hidden nodes in the ANNs was also varied to optimize performance. Optimal ANN performance based on percent correct classifications of test set data was achieved by ANN-30-30-6 (97%) and ANN-20-10-6 (94%), where the integers refer to the numbers of input, hidden, and output nodes, respectively. This performance equals or exceeds that obtained previoush (Welsh, W.J.; et al. Anal. Chem. 1996, 68, 3473) using 46 inputs from a so-called Window preprocessor (93%). KNN performance with 20 inputs (97%) or 30 inputs (90%) from the WP preprocessor also exceeded that obtained from the Window preprocessor (85%), while SIMCA performance with 20 inputs (86%) or 30 inputs (82%) from the WP preprocessor was slightly inferior to that obtained from the Window preprocessor (87%). These results indicate that, at least for the ANN and KNN classifiers considered here, the WP preprocessor can yield superior performance and with fewer inputs compared to the Window preprocessor.
UR - http://www.scopus.com/inward/record.url?scp=0030977730&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030977730&partnerID=8YFLogxK
U2 - 10.1021/ac9608836
DO - 10.1021/ac9608836
M3 - Article
C2 - 9105180
AN - SCOPUS:0030977730
SN - 0003-2700
VL - 69
SP - 1392
EP - 1397
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 7
ER -