Radiation exposure to hand surgeons' hands: A practical comparison of large and mini C-arm fluoroscopy

Michael M. Vosbikian, Asif M. Ilyas, Derek D. Watson, Charles F. Leinberry

Research output: Contribution to journalArticlepeer-review

32 Scopus citations

Abstract

Purpose To determine and compare the radiation exposure to surgeons' hands with large and mini C-arm fluoroscopy in a practical, clinically based model. Methods Two hand surgeons monitored radiation exposure to their hands with a ring dosimeter over a 14-month period using large and mini C-arm fluoroscopic units. One surgeon performed all cases with a large C-arm unit in a hospital setting, and the other performed all cases with mini C-arms in surgical centers. For each case, fluoroscopic time, the output displayed by the unit, radiation by time, and ring dosimeter absorption were recorded and analyzed. Results A total of 160 consecutive cases were reviewed with 71 cases and 89 cases in the large and mini C-arm groups, respectively. The median output displayed by the large C-arm was 0.7 mGy/case, and the median output displayed by the mini C-arm was 10.0 mGy/case. With output as a product of time, the median calculated values were 0.02 mGy/s for the large C-arm group and 0.28 mGy/s for the mini C-arm group. Cumulative ring dosimeter absorption to the surgeons' hands was found to be 380 mrem for 71 cases in the large C-arm group versus 1,000 mrem for 89 cases in the mini C-arm group. Conclusions In our model, the use of the mini C-arm resulted in more than a 10-fold increase in the rate of output and approximately double the dosimeter absorption to the surgeon's hand compared with the large C-arm. Although it has been shown that the mini C-arm produces less radiation scatter, in a practical model, it may not be a safer alternative with respect to the surgeon's hands. Based on these findings, we recommend that surgeons be more aware of radiation exposure risk, know their C-arm unit's specifications, and try to minimize radiation exposure.

Original languageEnglish (US)
Pages (from-to)1805-1809
Number of pages5
JournalJournal of Hand Surgery
Volume39
Issue number9
DOIs
StatePublished - Sep 2014
Externally publishedYes

All Science Journal Classification (ASJC) codes

  • Surgery
  • Orthopedics and Sports Medicine

Keywords

  • Fluoroscopy
  • large C-arm
  • mini C-arm
  • radiation
  • radiation exposure

Fingerprint

Dive into the research topics of 'Radiation exposure to hand surgeons' hands: A practical comparison of large and mini C-arm fluoroscopy'. Together they form a unique fingerprint.

Cite this